WESTERN STATES FIRE PROTECTION INSTALLED FIRE SPRINKLER SYSTEMS IN THE EMBASSY SUITES HOTEL IN KANSAS CITY
 
Embassy Suites
Western States Fire Protection installed fire sprinkler systems in the Embassy Suites Hotel, a 12 story building with a penthouse, in downtown Kansas City.

Only the first floor, basement and parking garage were previously fitted with sprinklers. Western States Fire Protection had to rework the systems in those areas to bring them up to current standards. This included replacing the existing fire pump.
 
Elevator Room
Elevator Room
A wet pipe fire sprinkler system was used throughout the building except in the electrical and elevator equipment rooms where firecycle systems were installed . Firecycle systems use a resetable detection design to protect from unnecessary water discharge. It turns itself on when there’s a fire and then turns itself off when the fire is out. If the fire should reignite, it turns itself on again and continues to cycle as needed.

In the parking garage there is a dry-pipe fire sprinkler system. In these systems pipes are pressurized with air instead of water. They are commonly used in unheated buildings where there is a potential for freezing.
 
Sprinkler Valve
Sprinkler Valve
Western States Fire Protection installed a new Edwards fire alarm control panel to monitor existing and new fire alarm devices such as flow switches, tamper switches and smoke detectors.

Edwards Fire Alarm Control Panel
Fire Alarm Control Panel
 
Living Area Suite
Living Area Suite
The retrofit of all suite levels meant holes had to be cut in the existing soffits in each room to install the fire sprinklers. The holes were then patched up and wallpaper and paint were selected to match the existing decor in each room.

In the atrium hallways sheet rock soffits were built to conceal new fire sprinkler piping. The wallpaper, painting, soffits and fire alarm work were all done under Western States Fire Protection's contract by subcontractors.

In the picture to the right you see a sidewall fire sprinkler head on the side of the soffit and a pendent sprinkler head on the bottom of the soffit.
 
Floor Soffit on Balcony
Soffit on Balcony
In the pool room you see poly coated upright pendant fire sprinkler heads. These fire sprinkler heads were used here because there is not a ceiling.

Pool Room
Pool Room
 
Banquet Room
Banquet Room
On the ceiling of the banquet room concealed fire sprinkler heads were used because they are less noticeable than other sprinkler heads.

Concealed Sprinkler Head
Concealed Fire Sprinkler Head
 
Looking Across the Atrium
Looking Across Atrium
Because the hotel was open during the course of the project, scheduling was an important consideration. Western States Fire Protection planned its work around the hotel's scheduled use of each room, kept noise to a minimum and kept work areas clean. During the Big 12 Basketball Tournament and again during the Big 12 Football Championship it was necessary to complete installation on the floors currently being worked on, demobilize and then remobilize after the events were over.